Page 230 Chapter 10: Troubleshooting
Control Devices (Rain Sensors, Freeze sensors, Etc.)
Many commercial sensor devices available in today's market
take advantage of the common ground configuration to control
watering operations. Devices such as rain sensors, freeze
sensors, moisture sensors, etc. employ a control system which
interrupts the common ground line of watering stations to control
the shutdown of stations.
These devices have inherent limitations:
1) They exhibit "contact bounce" or jitter when the on/off
threshold is reached. This may have adverse affects on
pump systems.
2) Since they interrupt common lines, non-irrigation
programs such as lighting programs are also affected.
3) It may be difficult to identify/interrupt "the" common
wire if multiple commons come in from the field.
When connecting a common interrupting device to the Evolution
DX2 controller, certain conditions must be met prior to
installation to prevent the aforementioned problems. The Rain
Master custom interface cable kit provides the appropriate
method for connecting control devices with continued operation
integrity of the Evolution DX2 controller.
The interface kit is available (with full installation instructions)
at no charge through the Rain Master Order department under
part number "DXCID-KIT".
To request the interface kit, please contact Rain Master direct at
(805) 527-4498.