Rain Master Irrigation Systems DX2 User Manual
Chapter 10: Troubleshooting Page 179
009 - Off Line
Figure 150: Warning 009-Off line
A satellite has lost hardwire communications with its submaster.
Hardwire communications occur between the submaster and its
satellites at the rate of once every 0.1 seconds. Loss of
communications may be temporary (power glitch) or permanent
(severed EV-CAB-COM communications cable). In either case,
irrigation will continue at the satellites without interruption as
long as the configuration does not utilize the Flow Max feature.
This message will be accompanied by a corresponding message
at its submaster, "HW COMM FAILURE."
Action:
Step 1 Hardwire communications failures may be caused by
any of the following: power failures, improper
hardwire connections at the communications board,
or broken/severed communications cable.
Step 2 Starting with the first satellite which is connected to
the submaster, examine the satellite address to verify
address XX-01 appears in the LCD display. If there
is no address and the controller is on, then a problem
related to the communications cable or its
connections has occurred somewhere between the
submaster and this unit. If the address is OK,
examine the satellite warning list for any related
warning messages, e.g. momentary power failure. If
address is OK and there are no related warnings,
proceed to the next satellite and troubleshoot as
above. Because the communications cable is wired
WARNING = OFF LINE 03/20/93