Rain Master Irrigation Systems DX2 User Manual
Page 184 Chapter 10: Troubleshooting
012 - Wind Upper Limit Exceeded
Figure 153: Warning 012-Wind Upper Limit
The wind upper limit has been reached. Upon receipt of this
alarm condition, the Central Control System automatically places
all satellites into the wind shutdown mode (only those satellites
within the confines of the wind microclimate are affected).
Programs which are running at the time the satellite goes into
wind shutdown mode automatically turn all outputs off (stations,
Master Valves, Pumps, etc.). These programs however, continue
to advance in time and will resume if the wind lower limit
conditions have been met. Wind limits can be modified and
reviewed at the Central Control Computer only.
Action: None. This feature is only applicable to Central
Control Systems.
WARNING = WIND UP LIMIT 06/21/96
12:30PM
22 MPH FOR 2 MIN |¾||½|