Rain Master Irrigation Systems DX2 User Manual
Chapter 10: Troubleshooting Page 217
A Station/Valve Does Not Water
Start
Ref. (10-3)
Are there warnings in base
screen display?
Does station light
turn on for station indicated in
display?
Ref. (2-14)
Refer to warning list (10-4) View and
take corrective action, then clear
warning
Yes
No
No
Yes
Yes
No
1
2
3
4
Ref. (10-3)
Are there warnings
in base screen
display?
Turn controller power off and verify cable
connections are properly made from DX2 main
board to station output board.
If connections correct and station light does not turn
on, return station output board to factory for repair.
A
Using Manual Station function, turn suspect station
# on for 5 minutes.
Ref. (8-12)
Refer to warning list (10-4) View and
take corrective action, then clear
warning
Yes
No
5
Is station
field wiring properly connected
at DX06 or DX012 station
output?
Ref. Station connection diagram (2-14)
Verify wiring and connections.