Chapter 10: Troubleshooting Page 191
Flow Max Warnings
019 - Flow Max - Flow Lower Limit Violation
Figure 160: Warning 019-FM Flow Low Limit
This warning appears FM flow lower limit at the submaster
whenever the measured flow is less than the expected flow
(lower limit failure). "SAT=" lists the address(es) of any
satellites which were irrigating at the time of the warning.
Example: Assume a submaster address of 35-00.
If the warning reads "SAT=1, 4, 5 GPM=90" then
each of the satellites 35-01, 35-04, 35-05 had one or
more stations which were on. Their combined
measured flow was 90 GPM which is less than the
programmed limit.
Action:
Step 1 Examine the warnings at the listed satellites to
determine which stations were on at the time of the
warning. Stations can be identified by viewing the
"FM STATION ADVANCE" warning at each of the
satellites.
Step 2 Alarm generation may be caused by mis-adjusted
valves, incorrectly established individual station
limits, large variations in static water pressure,
improper regulation, or line impediments.
Step 3 If station limits are suspected, manually turn each
station on and verify the lower limits. To manually
WARNING = FM FLOW LO LIM 05/30/96 04:45PM
SAT = 1, 4, 5 GPM=90 |¾||½|