Rain Master Irrigation Systems DX2 User Manual
Chapter 10: Troubleshooting Page 203
027 - Flow Max - Station Advance
Figure 168: Warning 027-FM Station Advance
This warning is issued to all Flow Max participants who have
stations on whenever either a FLOW UP LIM or a FLOW LO
LIM Warning (upper or lower limit failure) has occurred. The
"STA=" information indicates which stations were on at the time
the flow violation occurred. Upon receipt of this command, the
satellite will terminate irrigation for the listed stations and
automatically advance to the next station in the current program.
Future irrigation will not occur at the listed stations until this
alarm is CLEARED from the satellite/s.
Action:
Step 1 Review the Action information listed under the
FLOW UP LIM or the FLOW LO LIM warnings.
Step 2 Investigate individual station operation for listed
stations. (Refer to the Manual Test procedure)
Manually turn on each station individually and
visually inspect operation. Note the measured flow
readings and compare to both the upper and lower
limits which are set for this station. Check for any
broken or restricted heads, etc.
Step 3 IMPORTANT:
Upon resolution of problem, CLEAR all warnings at
the satellites.
WARNING = FM STA ADVANCE 05/30/96 04:45PM
STA= 1, |¾||½|
Commenti su questo manuale