Rain Master Irrigation Systems DX2 User Manual
Page 190 Chapter 10: Troubleshooting
018 - Short Circuit
Figure 159: Warning 018-Short Circuit
A short circuit problem was detected on a station or device. The
warning screen displays the stations and devices that were on at
the time of short circuit detection. This alarm will occur whether
or not station limits have been enabled or disabled. Upon
detection, the controller immediately turns the station(s) off and
advances to the next station in the program. This insures that no
physical damage occurs to the controller by drawing too much
current.
Action:
Step 1 Too much current for a station is caused by improper
field wiring or valve solenoid failure.
a. Examine the station field wiring and look for an
inadvertent connection from the station field
wire directly to the controller common
b. Look for a direct connection from the station
field wire to earth ground
c. Look for a shorted solenoid in the valve
d. For warnings displaying multiple stations,
identify the defective station/device using the
Multi-Station Diagnostics procedure
Step 2 IMPORTANT:
Upon resolution of problem, CLEAR all warnings at
the satellites.
WARNING = SHORT CIRCUIT 06/20/96 05:15PM
STA = PUMP, MV1, 1 |¾||½|