Page 162 Chapter 10: Troubleshooting
Warning Report (Alarms)
The Evolution DX2 series controller has the ability to
automatically notify the operator when problems occur, or
certain conditions arise.
The mechanism used is known as the warning report. The
Evolution DX2 controller may report on over 30 different
conditions. Each condition is date/time stamped and includes
additional information which may be helpful in troubleshooting
the problem. Up to 15 warnings may be saved in the controller
at one time. The user may delete the list of warnings at any time.
Because the controller operates intelligently, immediate operator
attention to alarms/warnings is not necessary. For example,
consider a station with a broken head (FLOW UPPER LIMIT
warning). Upon detection of this failure, the Evolution DX2
will:
• Turn the failed station off
• Advance to the next scheduled station in the program
• Mark this station as condemned (will not water again
until the alarm/warning is cleared)
• Report the failed station as a warning
Upon review of the warning, maintenance personnel would
repair the problem and then clear the warning at the controller
(this re-enables all irrigation at the station).