Evolution DX2 series Manuale Utente Pagina 46

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 45
Rain Master Irrigation Systems DX2 User Manual
Page 206 Chapter 10: Troubleshooting
030 - FM - Communications Failure
Figure 171: Warning 030 -FM Hardwire Comm Failure
This warning is generated at the submaster when using the Flow
Max feature. It indicates that hardwire communications were
lost or interrupted between one or more satellites which are Flow
Max participants. The warning is immediately followed by a
STOP WATER warning. This means that all irrigation at the
time the communications failure occurred will be terminated.
Action:
Step 1 Hardwire communications failures may be caused by
any of the following:
Power failures
Improper hardwire connections at the
communications board of any Flow Max
participant
Broken or severed communications cable
Step 2 Starting with the first satellite which is connected to
the submaster, examine the satellite address to verify
address XX-01 appears in the LCD display (Address
display should appear every seven seconds). If there
is no address and the controller is on, then a problem
related to the communications cable or its
connections has occurred somewhere between the
submaster and this unit.
If the address is OK, then examine the satellite
warning list to see if there are any related warning
messages, e.g. momentary power failure. If the
address is OK and there are no related warnings,
then proceed to the next satellite and troubleshoot as
WARNING = FM COMM FAIL
05/30/96 04:45PM